Differences are marked in red | SPATIUM M461 PCIe 4.0 NVMe M.2 500GB | SPATIUM M461 PCIe 4.0 NVMe M.2 1TB | SPATIUM M461 PCIe 4.0 NVMe M.2 2TB |
---|---|---|---|
Model Name | SPATIUM M461 PCIe 4.0 NVMe M.2 | SPATIUM M461 PCIe 4.0 NVMe M.2 | SPATIUM M461 PCIe 4.0 NVMe M.2 |
Capacity | 500GB | 1TB | 2TB |
Controller | PHISON E21T | PHISON E21T | PHISON E21T |
Flash Memory | 3D NAND | 3D NAND | 3D NAND |
Form Factor | M.2 2280 | M.2 2280 | M.2 2280 |
Interface | PCIe Gen4x4, NVMe 1.4 | PCIe Gen4x4, NVMe 1.4 | PCIe Gen4x4, NVMe 1.4 |
Compatibility | PCIe Gen4 / Gen3 / Gen2 / Gen1 | PCIe Gen4 / Gen3 / Gen2 / Gen1 | PCIe Gen4 / Gen3 / Gen2 / Gen1 |
Dimensions | 80.00mm (L) x 22.00mm (W) x 2.15mm (H) | 80.00mm (L) x 22.00mm (W) x 2.15mm (H) | 80.00mm (L) x 22.00mm (W) x 2.15mm (H) |
Sequential Read up to (MB/s) | 4700 | 5000 | 5000 |
Sequential Write up to (MB/s) | 1700 | 3200 | 4200 |
Random Read 4KB up to (IOPS) | 320,000 | 630,000 | 680,000 |
Random Write 4KB up to (IOPS) | 400,000 | 750,000 | 880,000 |
Maximum Operating Power (W) | 3.7 | 4.1 | 4.4 |
Idle Power PS3 (mW) | 50 | 50 | 50 |
Low Power L1.2 (mW) | 5 | 5 | 5 |
Operating Temperatures | 0°C – 70°C | 0°C – 70°C | 0°C – 70°C |
Storage Temperatures | -40°C – 85°C | -40°C – 85°C | -40°C – 85°C |
Terabytes Written (TBW) | 110 | 250 | 450 |
Mean Time Between Failure (MTBF) | Up to 1,500,000 Hours | Up to 1,500,000 Hours | Up to 1,500,000 Hours |
Limited Warranty | 5 Years, or the coverage for the maximum TBW as stated, whichever comes first. | 5 Years, or the coverage for the maximum TBW as stated, whichever comes first. | 5 Years, or the coverage for the maximum TBW as stated, whichever comes first. |
Advanced Features | TRIM (Performance Optimization, OS Support required)<br /> SMART (Self-Monitoring, Analysis and Reporting Technology)<br /> LDPC (Low Density Parity Check) ECC Algorithm<br /> End to End Data Path Protection<br /> APST (Autonomous Power State Transition)<br /> Pyrite (Encryption, Data Security) | TRIM (Performance Optimization, OS Support required)<br /> SMART (Self-Monitoring, Analysis and Reporting Technology)<br /> LDPC (Low Density Parity Check) ECC Algorithm<br /> End to End Data Path Protection<br /> APST (Autonomous Power State Transition)<br /> Pyrite (Encryption, Data Security) | TRIM (Performance Optimization, OS Support required)<br /> SMART (Self-Monitoring, Analysis and Reporting Technology)<br /> LDPC (Low Density Parity Check) ECC Algorithm<br /> End to End Data Path Protection<br /> APST (Autonomous Power State Transition)<br /> Pyrite (Encryption, Data Security) |
使用している画像や特徴は一例です。撮影条件やモニターの設定などにより、商品の色と写真が多少異なる場合があります。
製品の仕様、機能、および外観は、国により異なる場合があります。製品の詳細は最新の製品仕様ページをご参照ください。
仕向地や出荷時期により製品の仕様が異なる場合があります。また、予告なく仕様を変更することがあります。
実際の仕様につきましては、取扱販売店でご確認ください。